EasyManua.ls Logo

Mastervolt MASTERLINK MICC - User Manual

Mastervolt MASTERLINK MICC
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USERS MANUAL
MASTERLINK MICC
MASS INVERTER CHARGER CONTROL
MASTERVOLT
Snijdersbergweg 93,
1105 AN Amsterdam
The Netherlands
Tel.: +31-20-3422100
Fax.: +31-20-6971006
www.mastervolt.com
Language : English
Version : V4.0-301104

Questions and Answers

  • M
    mcampbellJul 31, 2025
    How to fix Mastervolt MASTERLINK MICC Controller when there is no display function?
    • R
      Rebecca NelsonJul 31, 2025
      If your Mastervolt Controller's display isn't working, the issue might be with the wiring. Check the wiring for any errors, especially the power supply connections at pin 1 and 2.
  • L
    Louis RichmondAug 4, 2025
    What to do if my Mastervolt MASTERLINK MICC Controller shows no amp reading?
    • W
      Wendy MorrisAug 4, 2025
      If your Mastervolt Controller isn't displaying an amp reading, it's likely a wiring problem. Check the wiring, paying close attention to the connections between the shunt and pins 3 and 4.
  • V
    veronicaknappAug 9, 2025
    Why is my Mastervolt MASTERLINK MICC showing no volt reading?
    • B
      Brenda RomeroAug 9, 2025
      If your Mastervolt Controller shows no volt reading, there may be an error in the wiring. Check the wiring, especially the voltage sense connections at pins 1, 2, 5, and 6.
  • R
    rrodriguezAug 13, 2025
    How to troubleshoot inaccurate amp readings on a Mastervolt Controller?
    • S
      Shawn HodgesAug 13, 2025
      If the amp readings on your Mastervolt Controller are inaccurate, it could be due to distortion on the shunt wiring. Replace the existing wiring with a twisted pair cable between the shunt and pins 3 and 4. Also, rerun the wires, keeping them away from equipment that might cause noise.
  • J
    john97Aug 18, 2025
    What to do if Time remaining function indicating '------' during discharge on Mastervolt MASTERLINK MICC?
    • W
      William FlowersAug 18, 2025
      If the 'time remaining' function on your Mastervolt Controller displays '------' during discharge, the shunt wiring might be reversed. Check the installation drawing and correct the wiring, paying close attention to the distinction between the battery side and the system side.
  • L
    Logan GonzalesAug 21, 2025
    Why is my Mastervolt MASTERLINK MICC not showing the voltage reading of the secondary battery?
    • K
      kennethwatersAug 22, 2025
      If your Mastervolt Controller isn't displaying the voltage of the secondary battery, the secondary battery may not be connected, or it may be wrongly connected. Check the wiring to pins 7 and 8. Connect a wire between the minus of the main battery and the minus of the secondary battery.
  • M
    Mario HillAug 26, 2025
    Why does the backlight of my Mastervolt MASTERLINK MICC switch off after 15 seconds?
    • D
      daltonalexanderAug 27, 2025
      The backlight on your Mastervolt Controller might be switching off after 15 seconds because the unit is in sleep mode. Press one of the buttons to exit the sleep mode.

Summary

GENERAL INFORMATION

Use of this manual

Guide for safe operation, installation, maintenance, and correction of minor malfunctions.

SAFETY GUIDELINES & MEASURES

Warnings and Symbols

Safety instructions and warnings marked with symbols and pictograms like 'i', 'CAREFUL', 'WARNING'.

Intended Use and Precautions

Use the MICC as intended, in a protected environment, follow guidelines, and be aware of special dangers like wiring and voltage.

INSTALLATION

Required Tools and Materials

Lists necessary tools such as saws, drills, spanners, and materials like shunts, cables, and connectors for installation.

Step-by-Step Installation Guide

Detailed steps for installing the Masterlink MICC, including cut-outs, shunt placement, and wiring connections.

Charger and Inverter Connection

Instructions on connecting cables between batteries, charger, and inverter before connecting the Masterlink MICC.

SYNCHRONISATION AND SETTING THE BATTERY CAPACITY

Synchronisation Process

Process to synchronize the meter with installed batteries after charging them for at least 24 hours.

Setting the Battery Capacity

Steps to set the battery capacity for accurate readings, noting it must be done when batteries are 100% charged.

OPERATION

Remote Control of the Battery Charger

How to switch the battery charger on/off via the "Charger" button and the meaning of related LEDs.

Remote Control of the Inverter

How to switch the inverter on/off using the "Inverter" button and the status of the Inverter-LED.

LOW BATTERY ALARM MENU

Voltage and Ah Alarm Points

Setting the low voltage threshold and low Ah discharge floor for the alarm, with system voltage detection.

INSTALL LEVEL

ADVANCED SETTINGS

GENERAL BATTERY INFORMATION

TROUBLE SHOOTING AND ERROR CODES

Trouble shooting Common Issues

Table listing common problems, their possible causes, and recommended actions for resolution.

Masterlink MICC Error Codes

List of error codes displayed by the Masterlink MICC, with descriptions and recommended actions.

TECHNICAL DATA

Mastervolt MASTERLINK MICC Specifications

General IconGeneral
Output Voltage12/24 V DC
DisplayLCD
DC System Voltage12/24 V
Protection classIP21
Input voltage range8 - 35 V DC
AC Inputs1
Alarm Outputs2
CommunicationMasterBus
Weight0.3 kg
HumidityMax 95% non-condensing
Input Voltage12/24 V DC