82 Matrix ETERNITY Quick Start
Mailbox Size:
• Default Mailbox size = 5 minutes for each mailbox. The maximum size of each 
mailbox can be of 999 minutes.
• Change the Mailbox size for mailbox depending upon the requirement of the 
Station user.
Maximum Message Length:
• Default Maximum Message Length = 15 seconds for each mailbox. Maximum 
message length can be of 999 seconds.
• Change the Message length of the mailbox depending upon the requirement of 
the Station user.
Ask Mailbox Password at Login:
• Default = Yes.
• You can also program it as ‘No’ i.e the station user will not be asked to enter the 
password when accessing the mailbox.
Message Notification:
• Default = No.
• Program it as ‘Yes’ for the mailbox depending upon the requirement of the 
station user.
Checking the VMS installation 
• Dial the VMS group number (default 3931) from the station. The call will be 
automatically answered by the VMS and you will hear the voice messages 
programmed in the VMS.
Disconnect tone Detection
• If you are using TWT trunk and have enabled DID (Auto Attendant) on the same 
trunk, enable Disconnect Tone Detection and program Disconnect Tone 
Cadence in ‘TWT Hardware Template’ assigned to this trunk.
• For more details refer, ETERNITY System Manual.