7
4.1 no reSiSTance TroUbleSHooTinG
1) SymPTom:
No resistance
2) SolUTion
a.Opentheframecoverandcheckwhetherthetensioncontrolworks.
b. When you adjust the tension control brake, please verify whether the wire moves and refer to the steps below to find the root cause.
SPEEDBRAKE(RIGHTSIDE)SLEDBRAKE(LEFTSIDE)
If the wire does not move, replace the SPEED BRAKE tension control Ifthewiredoesnotmove,replacetheSLEDBRAKEtensioncontrol
Check the ECB and spring connection Check the brake band connection