TECHNICAL DATA6 - 2
SE-44R / SE-44
Ultrasonic Sensor
www.maxcess.euMI 1026 1 A
Electrical connection Power supply
10V ... 15V at 40mA
Output signal
0 - 10mA
Pin assignment
Standards The SE-44 sensor was constructed in accordance with the
standards and regulations of the European Union. A Declaration
of Conformity is available.
1 Power supply
2 - Not assigned
3 - P-GND
4 - Output signal
X - key
Housing = shield
Figure 6.1: M12 connector, SE-44
2
1
3
4
X
4
1
3
2
X
1–Output signal
2 - Power supply
3 - P-GND
4 - Not assigned
X - notch
Housing = shield
Figure 6.2: M9 female connector, SE-44R
X
3
2
4
1
4
1
3
2
X