EasyManua.ls Logo

Maxon EPOS 50/5 - Table 3-48 STO Input Specification; Table 3-49 STO Output Specification; Figure 3-37 STO-OUT Circuit; Figure 3-36 STO-IN1 Circuit (Analogously Valid for STO-IN2)

Maxon EPOS 50/5
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup
Connections
EPOS4 50/5 Hardware Reference
3-46 CCMC | 2022-04 | rel10445
Table 3-48 STO input specification
Figure 3-36 STO-IN1 circuit (analogously valid for STO-IN2)
Table 3-49 STO output specification
Figure 3-37 STO-OUT circuit
Continued on next page.
Safe Torque Off inputs 1…2
Circuit type Optically isolated input
Input voltage 0…+30 VDC
Max. input voltage ±30 VDC
Logic 0 <1.0 VDC
Logic 1 >4.5 VDC
Input current at logic 1
>2 mA @ 5 VDC
typically 3.2 mA @ 24 VDC
Reaction time <25 ms
Safe Torque Off output
Circuit type
Optically isolated output with self-resetting short-
circuit protection
Max. input voltage ±30 VDC
Max. load current 15 mA
Leakage current <10 μA @ +30 VDC
Max. voltage drop
1.3 V @ 2 mA
2.5 V @ 15 mA

Table of Contents