Chapter 6
Operation Guide
◎ Please refer to Chapter 4 "Detailed Specifications" to select a suitable power
supply. To select an appropriate power supply, kindly refer to Chapter 4 "Detailed
Specifications.
◎ To ensure the peripheral working environment of the laser meets safety
requirements, consult Chapter 2 "Safety Information.
◎ Prior to laser welding, please wear the provided soundproof earplugs for your protection.
2 -
Electrical Power Connection Guidelines
1. The laser's power input line must be connected to a single-phase alternating
current (220VAC) using a 25A industrial power source.
2. It is strictly prohibited to connect the power cord directly to a household electrical
outlet.
3. Ensure that the power cord is connected to the appropriate voltage and
phase: L=220VAC, N=0VAC, and PE=ground. Verify that the wiring is correct
before operating the machine, and never neglect the PE connection.
For enhanced safety, Maxphotonics strongly recommends connecting a 32A circuit
breaker (air switch) in series between the power supply and the laser. Ideally,
position the power supply near the device's power supply unit for easy disconnection.