Method 2: Access the Professional mode.
In the Settings, set reasonable firing duration and interval times:
1. 1.Ignition duration: 150ms (this parameter affects the size of the welding striatum)
2. 2.Interval time: 40ms (this parameter affects the interval between two striatum) Fish scal
14-
How To Use The Fish Scale Function
Method 1: Enable the fish scale pattern on the home page
The fish scale pattern has built-in default parameters, so you don't need to set them.
Simply turn on the switch:
1. Firing time: 150ms
2. Interval: 40ms
For optimal fish scale effects, use the wire feeding machine parameters and set the
wire feeding speed according to 7-10.
e
pattern welding (In this mode, only the laser is turned off during the interval, and other
settings such as on/off time do not affect or take effect) Simply set the spot welding duration
and interval to produce the fish-scale welding effect. Note: It is recommended to use fish-
scale pattern welding at 50% power. If it is necessary to use fish-scale pattern under high
power, do not use a large welding angle and use appropriate positive defocus (gun barrel
scale: +2 to +4 range) to increase gas flow and reduce welding splash. This can prolong the
service life of the protective lenses.
Method 3: Use pulse wire feeding mode (recommended).
In the wire feeder parameters, select "pulse":
1. Pulse period: 140ms
2. Pulse wire feed speed: 10mm/s
3. Pulse smoothness: 20%