6. Specification
Capacity
Topology
Input
Output
Battery
Charger
Nominal Voltage
Voltage Range
Frequency Range
Power Factor
Nominal Voltage
Voltage Regulation
Frequency Stability
Waveform
Power Factor
Distortion
Overload Capacity
Transfer Time
Type
DC Voltage
Backup Time
Recharge Time
External Battery
Connector
1000VA 2000VA 3000VA
3~30 Min
4.5~40 Min 4.5~45 Min
< 8 Hour Recovery to 90%
Option
Double Conversion
120Vac / 230Vac( 110,115,120,127Vac/
208,220,230,240Vac Configurable)
60~138Vac /120~276Vac
50 /60Hz ± 0.5Hz ( Auto-sensing )
>0.95 ( full load condition )
120Vac / 230Vac ( 110,115,120,127Vac/
208,220,230,240Vac Configurable)
+3% ( Non-Linear Load )
50 /60Hz ± 0.3Hz ( Battery Mode )
True Sine Wave
0.7 lagging to 1
<5% ( Non-Linear Load )
105~125% for 1 min./ 126~150% for 10 sec./>150% Trip Immediately
@AC mode, UPS transfer to bypass/ @Battery mode, UPS shutdown
0 ms
Sealed, Maintenance-free Lead Acid
24Vdc
Specification
- 22-
72Vdc 96Vdc
Charging voltage
Standard
Extended
Charging current
Standard
Extended
27.6V ± 0.3V
27.0V ± 0.3V
1.0A max
8.0A max
82.5V ± 0.5V
82.5V ± 0.5V
110V ± 0.5V
110V ± 0.5V
0.8A max
10.0A max
0.8A max
10.0A max
Power Line
Surge
Suppression
EMI / RFI Noise
Filter
Joules
Up to 60 Db ( @1MHz )
250 Joules 375 Joules 375 Joules