PAGE 22
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
DRIVE MOTOR & BELT SWITCH
HEATER – SINGLE ELEMENT (ELECTRIC DRYER)
HEATER – GAS VALVE (GAS DRYER)
WATER VALVE
Figure 16 - Strip Circuits.
L1
CYCLE
CONTROL
UNIT
DRIVE MOTOR
CENTRIFUGAL
SWITCH
N
DOOR SWITCH
G-Y
W
MAIN
START
3M
5M
6M
1.4-2.6 Ω
1.4-2.8 Ω
2M
1M
LBU
P9-2
L1
P8-4
DOOR
MOTOR
P9-1
BELT
SWITCH
W
NC
NO
4M
BK
T
BU
W
BK
ELECTRIC ONLY
THERMAL FUSE
LBU
L1
G-Y
3M
5M
6M
2M
1M
CYCLE CONTROL UNIT
HEATER
RELAY
K2
N.O.
COM
BK
THERMAL
CUTOFF
HI LIMIT
THERMOSTAT
HEATER
OUTLET THERMISTOR
INLET THERMISTOR
10K
50K
R
R
R
R
L2
P4-3
P4-6
P4-2
P4-1
CENTRIFUGAL
SWITCH
OUTLET TEMP
OUTLET TEMP
RTN
INLET TEMP
INLET TEMP
RTN
R-W
R
BK
10
R
R
BK
L1
CYCLE
CONTROL
UNIT
HEATER
RELAY
K2
COM
BK
R
OUTLET THERMISTOR
INLET THERMISTOR
10K
50K
THERMAL
FUSE
HI LIMIT
THERMOSTAT
THERMAL
CUTOFF
GAS VALVE ASSY
BU
R
50-500
IGNITOR
VALVE 1
VALVE 2
FLAME
SENSOR
MOV
BK
IG
IGR
IV
2
13
4
5
FS1
1365 ± 25
560 ± 25
1220 ± 50
3V
R
BK
CENTRIFUGAL
SWITCH
G-Y
3M
5M
6M
2M
1M
W
N
R
BU
R-W
R-W
P14-3
P14-6
P14-2
P14-1
NC
NO
N.O.
DOOR SWITCH
OUTLET TEMP
OUTLET TEMP
RTN
INLET TEMP
INLET TEMP RTN
MODEL
MODEL RTN
P14-4
P14-5
BK
BK
JUMPER REQUIRED
FOR GAS DRYERS
LBU
BK
HOLD
R
R
FS2
CYCLE
CONTROL
UNIT
BK
WATER
VALVE
RELAY
WATER VALVE
R
510-590
L1
P9-2
BK
DRIVE
MOTOR
CENTRIFUGAL
SWITCH
N
DOOR SWITCH
G-Y
W
MAIN
START
3M
5M
6M
1.4-2.6
1.4-2.8
2M
1M
LBU
LBU
MOTOR
BELT
SWITCH
W
NC
NO
4M
BU
W
N.O.
COM
ELECTRIC ONLY
THERMAL FUSE
P9-1
P8-5
MOTOR CS
L1
BK-W
BK-W