3.4 Opto-Isolated Pulse Output Hook-Up
The outputs are open collector transistor outputs used to communicate with or activate external devices.
Opto-isolated output with collector and emitter terminals oating and freely connectable
Maximum switching voltage: 40 VDC
Maximum switching current: 100mA
Maximum saturation voltage between collector and emitter 1.2V@100mA
Maximum switching frequency (load on the collector or emitter, RL=470Ω, VOUT=24VDC): 1250Hz
Maximum reverse current bearable on the input during an accidental polarity reversion (VEC): 100mA
Isolation from other secondary circuits: 500 V
IMPORTANT
Digital outputs are not isolated from each other. All digital outputs MUST use the same power source.
i
Figure 13. Opto-Isolated Pulse Output Diagram
OUT 1
OUT 2
COMMON
EMITTER
OPTO ISOLATED OUTPUTS
18
17
19
3.5 Opto-Isolated Input
Opto-isolated input
500 V isolation
2-40 VDC on voltage
Input programming per input menu, will perform functions set to ON.
Input example:
Figure 14. Opto-Isolated Input Diagram
10K
24V
+
-
Push button
switch
15
16
30124-60 Rev. 1.2 | 16DEC2019
Page 10
CONNECTING WIRES TO TERMINALS
ProComm