11.7
Coffee doses programming
This submenu allows programming the coffee doses. Proceed as follows:
Prog. doses
Prog. doses
Enter into the programming menu
Scroll the menu till you have reached the “ Prog. doses”
submenu
Confirm in order to enter the designated submenu.
All dose
key led’s come on (both red and green)
Press the dose key to be programmed; during coffee
preparation, the dose’s green led will blink
Wait for dispensing; to confirm the dose press again the
selected dose key
^
For models with 2-3 groups is possible to program simultaneously all of the machine’s push button touch pads using only
the right push button touch pad. The programmed doses from the right group will be automatically transfered to the other
groups, too. It is however advisable to check the programming of the other push button touch pads.
Repeat this operation for the other dose keys
After finishing the programming,
exit from the submenu
M
11.6
Single coffee counters
This submenu allows to view and reset the number of selections made by a certain dose of the touch pad. Proceed as follows:
In order to reset the single count doses, proceed as follows:
•Enter into the “Single count” submenu;
•Simultaneously press the display’s keys “ ” and “ ”;
•On display will appear the following page:
•In order to confirm, press the key “ ”; on display will appear the “Single count” submenu, as follows:
Reset. counting?
NO YES
^
Coffees
Gr: 1 D: 1
0
Single count
Coffees
Gr: 1 D: 1
z
n
: the number of selections made by dose Y
from group X
Coffees
Gr: X D: Y
n
Enter into the programming menu
Scroll the menu until reaching the desired submenu
By pressing the touch pad’s dose key is possible viewing the
number of selections made with that key
Exit from the submenu
^
M
Confirm in order to enter the designated submenu. On
display is viewed the counting for one espresso from the
right brewing group of the coffee machine
When resetting the counting, all single count doses will be simultaneously reset.
i
After the number of selections made with a certain key reaches 999.999 value, the counting will restart from zero.
i
SAE Display