Winterizing the RV with a winterizing uid
Winterizing the RV with a winterizing uid is only possible with an installed bypass kit (not in scope
of delivery)
Refer to “Connection diagrams” in manufacturers booklet for all letters referred to in the following
description.
Winterizing AquaGo basic/ AquaGo comfort
1. Close valves A and B.
2. Open valve C.
3. Drain the appliance (“Draining the water and cleaning the water inlet lter” on page 56).
4. Flush the RV’s water system with a suitable winterizing uid according to the supplier’s or RV manufacturer’s
guidelines.
Winterizing AquaGo comfort plus
1. Close valves A, B and E.
2. Make sure that valve D remains in the closed position.
3. Open valve C.
4. Drain the appliance (“Draining the water and cleaning the water inlet lter” on page 56).
5. Flush the RVs water system with a suitable winterizing uid according to the supplier’s or RV manufacturer’s
guidelines.
6. Close all faucets (if open).
7. Open valve D.
8. Wait until winterizing uid has drained. Collect escaping uid in a suitable vessel.
9. Close valve D.
Maintenance
Repairs must be performed by a certied service technician. Truma recommends that the appliance be serviced annually
by a certied service technician. Verify proper operation after servicing.
High temperatures or repair attempts while the gas supply is turned on may
result in scalding injuries!
Turn OFF the electrical power supply and the LP gas supply before starting
maintenance and repair work.
Allow the appliance to cool down.
Never actuate the pressure relief valve as long as the appliance is still hot.
WARNING