58
Decalcication
Risk of damage in frost conditions.
In frost conditions, ambient temperatures below 39 °F (4 °C), there is a risk that
water in pipes, faucets and appliances could freeze. This can cause considerable
damage.
Do not decalcify the appliance in frost conditions.
NOTICE
Decalcication Frequency
Lime scale occurs especially as a result of precipitation from “hard” water. The appliance must be decalcied regularly
depending on water hardness and hot water consumption.
Recommended decalcication frequency per year
Very Hard
>180
1 2 4
Hard
121-180
1 1 3
Moderately Hard
61-120
1 1 2
Soft
0-60
1 1 1
Use*
Low Normal High
Water Hardness
Mg/l CaCO3
* Hot water consumption (approximately)
low 635 gallons/year 2400 l/year
normal 1585 gallons/year 6000 l/year
high 6350 gallons/year 24000 l/year
Decalcication (models without control panel)
Models AquaGo basic without control panel:
You can have these models decalcied by a Truma service partner. Please contact the following address:
Truma Corp.
825 East Jackson Blvd.
Elkhart, IN 46516,USA
Toll Free 1-855-558-7862
Fax 1-574-538-2426
info@trumacorp.com