Injuries caused by the Easy Drain Lever!
When the Easy Drain Lever is folded out, it protrudes
beyond the side wall of the vehicle.
When walking past or stooping down, make sure
that you and others have sufcient distance.
CAUTION
7. Open the latch with your thumb while pulling
the Easy Drain Lever down as far as it will go.
8. Remove the water inlet lter (or heating cartridge)
as shown in Fig. 10 and rinse it with clean water.
9. Inspect the O-rings on the water inlet lter
(or heating cartridge) for cracks. Change the lter
assembly (spare part, refer to “APPENDIX C – Spare
Parts (all models)” in manufacturers booklet)
if there are cracks.
Danger of crushing/pinching of ngers when the Easy
Drain Lever is closed!
Never put ngers between the Easy Drain Lever
and water inlet lter or latch.
CAUTION
If, during installation, it is difcult to install
the lter cartridge, use a small amount of soap on
the O-rings. Never use grease because the O-rings
are not resistant to grease.
10. Install the water inlet lter as shown in Fig. 10.
Observe the correct installation position and close
the Easy Drain Lever until it is locked by the latch.
You can hear a “clicking” sound as the
Easy Drain Lever engages.
11. Insert and close the access door (refer to
“Closing the access door” on page 48).
FIG. 10
*Or heating cartridge

Table of Contents