Trouble Shooting
When entering fault mode, the display will ash the LED lights to indicate the fault code. This will be indicated by:
2 long ashes of 2 seconds followed by a sequence of ashes with a 0.5 second interval. The number of quick ashes
indicates the fault code on the table below.
Times of
ashes of LED
Cause of trouble
1 Failure of second start
2 Termination of the third time of combustion
3 Power voltage out of specied range
4 Combustion chamber temperature too high during self-check period
6 Broken circuit or short-circuit of temperature sensor
7 Broken circuit or short-circuit of fuel pump
8 Broken circuit, short-circuit, or rotation clogging of fan motor
9 Broken circuit or short-circuit of glow plug
10
Ambient temperature over high before starting or furnace body temperature over
high during heating process
11 Broken circuit or short-circuit of overheating sensor
12 Broken circuit or short-circuit of control switch
13 Maintenance reminder: More than 800 hours of work time
14 Failure of controller
Protecting from Mould
Mould is very difcult to clean once a porous surface is affected. There are several ways you can prevent the
occurrence of mould on your caravan.
Never leave your camper packed away wet. If you must leave a campsite with wet canvas or a damn interior, be sure
to open and dry out your tent thoroughly at the very rst opportunity when you get home. Mould can develop in just
a couple of days so don’t take the risk.
When packing up dry, it is important to check under the mattress
that there is no build-up of condensation overnight. Body heat on
a mattress can create enough temperature difference with the
exterior for moisture to form under it. If left unchecked this can
cause mould when your caravan is stored.