6. MAINTENANCE
The Hawk actuator is designed to provide robust and precise operation while keeping maintenance to a
minimum. However, adequate preventative maintenance procedures are paramount to extending the life
of any mechanical device, including the Hawk, and are highly recommended.
6-1 Quarterly Inspection/Maintenance
It is recommended that visual inspections are performed on a quarterly basis to help identify easily
correctable mechanical issues. Quarterly inspection checks should include, but not be limited to, the
following:
Verify that the hydraulic fluid level is correct
Are tubing and fitting connections tight
Are mounting bolts and screws fastened correctly
Is there hydraulic fluid pooling on or below the actuator
Are cable connections secure at both the HPS and Control Enclosure
Are there cuts or excess wear in cables
Is there moisture or dirt in the HPS or Control Enclosure
Is the HMI responding accurately to user input
Is the actuator hunting or unable to hold a position
Is the actuator responding accurately to control signals
Is the position feedback signal accurate and stable
6-2 Five Year Inspection/Maintenance
In addition to the quarterly visual inspection it is recommended that the following maintenance is
performed at five (5) year intervals:
Quarterly visual inspection
Install soft goods repair kit (includes cylinder, manifold, and HPS soft goods)
Install accumulator/reservoir soft goods repair kit, if applicable
Replace HPS solenoids
Purge and replace hydraulic fluid