SYMPTOM PROBABLE CAUSE REMEDY
EEP.E1
CONFIG parameters are not correctly set
Re-set CONFIG parameters as technical manual
instructed.
EEP.E2
USER parameters are not correctly set
Re-set USER parameters per the Technical
manual
CAL.Er
1. Input data or loaded weight is too small,
too big
2. Weight signal is unstable, un-linear
1. Input correct data, load correct weight
onto platform.
2. Return the scale for repair
Cannot zero the
display
1. Load on scale exceeds allowable limits.
20%FS
2. Load on the scale is unstable
1. Remove load from the scale.
2. Wait for the load to stabilize. then press the
ZERO/ON/OFF key to zero the display
1. Max. CAPACITY
not same as
marked on
overlay
2. Any function
invalid
3. Any measuring
units missed
CONFIG and USER parameters are not correctly
set
Re-set CONFIG and USER parameters per the
Technical manual
Weighing is not
accurate
1. An object is stuck between the load cell
and scale base
2. Load cell received a heavy impact
3. The scale is at a location far from Chicago
1. Remove the object
2. Perform Linearity calibration
3. Loose the shipping protection screws.
4. Place the load on the center of the
weighing platform
PS103 www.measuretek.net .17