Page 30 Micro 19-XD - Operator’s Manual
July 2020Section 11 - Maintenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualified service technician.
ART_5000
Hydraulic
Unit
FULL
Component
Tray
ADD
No. Item Specification Frequency
1
Hydraulic
Reservoir
Mobile Fluid DTE 10, DTE 13 M, or
AW32
Do not substitute other fluids as
pump damage may result.
Fill to the middle of the dipstick with
platform in the stowed position.
Routine Maintenance
Check hydraulic oil level every week
Scheduled Maintenance
Change yearly or every 600 hours, whichever
occurs first
2
Hydraulic Cap
Breather Filter
Breather Filter (located inside Filler
Cap)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours, whichever
occurs first
Severe Conditions - very dusty, exceptionally
hot or exceptionally cold conditions
Change every three months or 150 hours,
whichever occurs first