11
Connection to the 960IPS is via an industrial M8 4 Pin connector. With the following
pin-outs:
2 4
1 3
Male connector on Bar
4 2
3 1
Female connector on Cable
Pin Colour Function Specication
1 Brown 24V (21-27V)
2 White Clean Pin & Fault Alert Output 0V / 24V
3 Blue 0V / Ground
4 Black Fault alert output 0V/24V
Connection using Meech 24V DC power supply
Meech 24V DC supplies are grounded internally. It is important that the mains
connection oers a ground connection. Two-pin outlets without a ground connection
must not be used, unless the ground post on the 960IPS bar is connected to ground.
The switchmode power supply has a standard IEC C13 mains socket and a 2000mm
HT cable to M8 Connector. A break-out wire from the switchmode power supply
provides the Clean Pin Alert output signal and fault alert.