MAC/MTT-OPS-1
26 FEB 2019
SECTION 4
Normal Operations
4-5
4. Water Level – Drain to desired level.
Do not operate the water pump in a dry sump.
Dry operation will result in shaft seal damage.
Once operations are complete:
5. DRAIN Switch – OFF
6. PUMP Switch – OFF
Do not engage/disengage the water pump
above LOW IDLE. Engaging/disengaging the
water pump above low idle will result in water
pump component damage and reduced
service life.
7. Cab Control SYSTEM/POWER Switch – OFF
Hose Reel
1. Hose Nozzle – CLOSED
2. Hose – Deploy desired length.
3. Gate Valve – OPEN
4. Cab Control SYSTEM/POWER Switch – ON
5. PUMP Switch – ON
Do not engage/disengage the water pump
above LOW IDLE. Engaging/disengaging the
water pump above low idle will result in water
pump component damage and reduced
service life.
6. Vehicle RPM – SET
7. Hose Nozzle – OPEN as desired.
Once operations are complete:
8. Hose Nozzle – CLOSE
9. Vehicle RPM – LOW IDLE
10. PUMP Switch OFF
Do not engage/disengage the water pump
above LOW IDLE. Engaging/disengaging the
water pump above low idle will result in water
pump component damage and reduced
service life.
11. (If Equipped) Cab Control SYSTEM/POWER
Switch- OFF
12. Gate Valve – CLOSED
13. Hose – Reel in and stow hose nozzle.
Water Circulation System
1. Fill water tank with appropriate fluid.
2. Start engine.
3. Cab Control SYSTEM/POWER Switch – ON.
4. PUMP Switch – ON
Do not engage/disengage the water pump
above LOW IDLE. Engaging/disengaging the
water pump above low idle will result in water
pump component damage and reduced
service life.
5. DRAIN Switch ON. (Opens BFV that allows
water pressure to mix water tank contents)
Once operations are complete:
6. DRAIN Switch – OFF.