MAC/MTT-OPS-1
26 FEB 2019
Appendix
MAC/MTT Operators Checklist
A-5
MAC/MTT-OPS(CL)-1
26 FEB 2019
16. MTT RH Hydraulic Hoses and Cabling – CHECKED
FOR SECURITY AND LEAKS.
17. (If Equipped) Front Bumper Spray Heads and
Plumbing – SECURED AND SET
OPERATIONS
Use these procedures to safely operate the standard
and optional systems installed on the MEGA water
tanker.
Limit water pump operation to 2.5 minutes when in a
no-flow condition (no flow from spray heads, dump
bar, water cannon, drain valve or hose reel). Water
pump operation in a no flow condition will cause
overheating of the water pump and damage to the
shaft bearings.
Spray Head System
Operating more than 3 spray heads simultaneously
will greatly reduce the width and flow of active spray
heads.
1. Cab Control SYSTEM/POWER Switch – ON
N-4