EasyManua.ls Logo

Megger DLRO10 User Manual

Megger DLRO10
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DLRO10 and DLRO 10X
Digital Low Resistance Ohmmeter
User Guide
User Guide
DLRO10 and DLRO10X
Digital Low Resistance Ohmmeter

Questions and Answers:

Megger DLRO10 Specifications

General IconGeneral
Resolution0.1 µΩ
ProtectionIP54
Test Current10 A
Resistance Range0.1 µΩ to 2000 Ω
DisplayLCD
Power SupplyRechargeable battery
Operating ModesNormal, Auto, Continuous
Accuracy±0.2%

Summary

Safety Warnings and Precautions

General Safety Precautions

General safety warnings and precautions for using the instrument, including circuit de-energization.

Battery Safety

Safety warnings and precautions concerning the instrument's lithium-ion battery pack, including handling and disposal.

Specific Safety Notes

Details specific hazards like inductive circuits and neck strap safety.

Symbols Used on the Instrument

General Description of DLRO10 and DLRO10X

DLRO10 and DLRO10X Overview

Describes the DLRO10 and DLRO10X low resistance ohmmeters and their core technology.

Instrument Features

Details key features such as four-terminal measurement and battery power.

DLRO10 Controls and Indicators

Explains the controls and indicators on the DLRO10 instrument panel.

General Operation - DLRO10

Brightness Control and Test Current Indicators

Instructions for adjusting brightness and understanding test current indicators.

DLRO10 Indicator Lamps

Explains the function of Noise, 'C'/'P', and 'V'/'I' warning lamps.

General Operation - DLRO10X

DLRO10X Top Panel Controls

Details the controls and features located on the DLRO10X top panel.

DLRO10X Main Menu and Warnings

Explains the DLRO10X Main Menu screen and its warning messages.

Discharge Current Warning

Details the warning message for discharge current flow after a test.

Menu Navigation

Explains how to navigate and use the instrument's menu system.

Test Menu and Options Menu

Explains how to select test modes and access instrument options.

Retrieve Stored Results

Instructions for recalling stored test results to the display or PC.

Download Data

Explains how to download stored data to a PC via the RS232 port.

Passbands Configuration

Details how to set upper and lower limits for test result pass/fail signalling.

Set Clock and Delete Data

Instructions for setting the clock, date, and deleting stored data.

Storage Settings

Details how to set the default data storage option (always store or never store).

Range Menu

Explains how to select the maximum test current from the Range Menu.

Entering Notes in Memo Screen

Instructions for entering notes into the memo screen for test results.

Test Result Storage

Information on test result numbering, memory capacity, and data management.

Keypad Operation

Explains the operation of the instrument's alphanumeric keypad.

Test Modes

Normal, Automatic, and Continuous Modes

Explains Normal, Automatic, and Continuous modes for resistance measurement.

Inductive Mode

Details the Inductive mode for measuring loads with inductive components.

Undirectional Mode

Explains the Undirectional mode for forward-current-only measurements.

Test Techniques and Applications

Using Duplex Test Leads with Indicator Lamps

Guide on using duplex test leads with indicator lamps for testing.

Using Duplex Handspikes and Test Sequence

Instructions for using handspikes and details the test sequence.

Test Lead Resistance and Overheating

Discusses test lead resistance limits and potential overheating issues.

Battery Module and Care

The Battery Module

Describes the features and function of the battery module.

Battery Charging

Provides instructions and guidelines for charging the battery module.

Battery State Indicator

Explains how to interpret the battery state indicator.

Standard Charging and Warning

Details standard charging and provides a warning about battery voltage.

Specifications

Resistance Ranges and Specifications

Detailed specifications including ranges, accuracy, display, and measurement modes.

Data, Battery, and Environmental Specifications

Covers data transfer, battery capacity, charging, temperature, humidity, and altitude.

Safety, EMC, Dimensions, and Weight

Information on safety compliance, EMC standards, physical dimensions, and weight.

Trouble Shooting

Error Messages and Actions

Lists common error codes, their messages, and required troubleshooting actions.

Accessories

Standard and Supplied Accessories

Lists standard accessories and test leads supplied with the instrument.

Optional Accessories and Power Unit

Lists optional accessories, carrying case, calibration shunts, and power supply unit.

Optional Test Leads

Lists additional optional test leads available for purchase with part numbers.

Test Leads with Inline Connectors

Information on test leads that feature inline connectors.

Repair and Warranty

Repair Services and Contact

Information on instrument repair, spare parts, and approved repair companies.

Returning Instrument and Warranty

Guidelines for instrument return, declaration of conformity, and disposal.

Battery Disposal Instructions

Details on the disposal of lithium battery packs and coin cells in accordance with regulations.

Related product manuals