85-03-00955 Page| 13
16" MINIMUM TO SIDE WALL
FROM SIDE EDGE OF
VISIBLE GLASS
8 3/16 TO VENT
PIPE CENTER
19 1/2 MIN
DEPTH
48 1/4 MIN ROUGH
FRAMING WIDTH
16" TO GUIDE EDGE
PROJECTIONS WITHIN
HATCHED AREAS ARE
DEEMED SAFE!
16"
CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES
CLEARANCE TO SIDE WALL PROJECTIONS
Any side wall adjacent to Left or Right side of this appliance protruding out more 16" in from of the front surface of the vis-
ible glass door and if perpendicular to the front surface of the glass door must be located a minimum of 16" from the side
edge of the visible glass door.
1/2" CLEARANCE
FROM BACK
0" CLEARANCE FROM
TOP STANDOFFS
1/2" CLEARANCE
FROM SIDES