85-03-01147-D ML60
Installation and Operating Instructions
MODEL NO. ML60 FULLVIEW DIRECT VENT GAS FIREPLACE HEATER
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result causing property damage, personal injury or
loss of life.
AVERTISSEMENT. Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquids inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gasses, unless a
certified kit is used.
Cet appareil peut être installé dans une maison
préfabriquée (É.-U. seulement) ou mobile déjà installée à
demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de
gaz indiqués sur la plaque signalétique. Une trousse de
conversion est fournie avec cet appareil.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and must be installed.
Une barrière conçue pour réduire le risque de brûlures
du verre chaud est fournie avec cet appareil et doit être
installée.
Question and Answer IconNeed help?

Do you have a question about the Mendota ML60 and is the answer not in the manual?

Summary

Important First Steps

Child Safety Precautions

Safety warnings for children regarding fireplace operation and proximity to hot surfaces.

Initial Firing and Curing

Steps for initial firing and curing to remove manufacturing residues and odors.

Hot Surface Safety

Information about normal hot surface temperatures and necessary safety precautions.

Periodic and Annual Cleaning

Requirements for regular cleaning and maintenance of the fireplace for optimal performance.

General Information and Safety

Safety and Warning Guidelines

Covers building permits, inspections, cautions, and general safety for installation.

Key Safety Warnings

Important safety warnings including California P65, high altitude, and general operating hazards.

Massachusetts Installation Requirements

Specific installation requirements for the Commonwealth of Massachusetts.

Technical Specifications and References

General Technical References

Details on curing instructions, inspections, and pre-ignition verifications.

Mechanical Technical References

Covers installation planning, clearances, dimensions, features, and venting.

Electrical Technical References

Details on AC power requirements, connections, and backup DC power installation.

Plumbing Technical References

Information on gas supply requirements, line sizing, pressure, and drip legs.

Installation Guide

Installation Preparation

Checklist, unpacking, component inventory, and initial unit handling procedures.

Component Installation and Conversion

Includes door, light, and gas conversion procedures, plus burner and pilot checks.

Venting Installation and Adjustments

Comprehensive guide to vent system installation, charts, clearances, and damper adjustments.

Final Setup and Checks

Instructions for log set installation, lighting, and final operational checks.

Homeowner Information

Aesthetic and Heating Information

Discusses aesthetic options and heating performance features of the fireplace.

Operating Your Fireplace

Guide to remote control functions, modes, lighting, and gas shutoff procedures.

Frequently Asked Questions

Answers to common questions on gas smell, model numbers, power outages, and maintenance.

Maintenance Information

Maintenance Procedures

Covers periodic inspections, glass cleaning, annual maintenance, and burner checks.

Parts and Service Access

Details on accessing components and lists of parts for blowers, lights, gas train, and glass frame.

Warranty Qualification and Service

Installation and Homeowner Verification

Checklist for final installation steps and homeowner orientation.

Warranty Coverage and Policy

Details the limited lifetime warranty, its terms, conditions, and exclusions.

Mendota ML60 Specifications

General IconGeneral
ModelML60
TypeIndoor Fireplace
Vent TypeDirect Vent
Control TypeRemote Control
Ignition TypeElectronic Ignition
WarrantyLimited Lifetime Warranty
Fuel TypeNatural Gas or Liquid Propane
BTU Input (NG)60, 000 BTU
BTU Input (LP)60, 000 BTU
Glass DoorYes