EasyManua.ls Logo

Mendota ML60 - Final Setup and Checks

Mendota ML60
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85-03-01147 ML60 Page 70
5.12 LOG SET/ MEDIA INSTALLATION
There are many options for log sets and media kits to compliment your new Mendota fireplace. To learn more about all the log
set and media kit options available please consult your local Mendota dealer.
Installation Instructions for each log set are included with the individual log set. Follow those instructions to install one log set.
Note: Installer, save and give the copy of the Log Set Installation Instructions to the homeowner for future
references.
5.13 LIGHTING CHECKLIST
Be sure to check these items before final operation of the Fireplace.
All items on "Installation Checklist" must be completed.
Carefully follow all lighting and log installation instructions. Make certain that pilot flame and burner light correctly.
Gas leaks and gas pressures prior to installing facing materials is checked.
Fresh batteries are in remote control. Follow “First-Time Lighting Instructions” to synchronize the remote control and the
ignition module.
Air shutter opening 0" to ⅛" natural gas or ¼” to ½” LP gas is checked.
Flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are "twist
locked" and leak proof, the vent cap is "right side up”. Do not proceed with operation if flame is "lifting off" burner.
DO NOT proceed with operation unless burner cycles "on/off" without delays and the flame is "stable" and not "lifting" off
burner after 5 minutes of initial ignition.
Caution: If ignition system goes into lockout mode, be sure to wait a minimum of five minutes before
relighting.