HURTH V-DRIVE TRANSMSSION SERVICE MANUAL NUMBER 23
Page 8D-16 90-861326--1 MARCH 1999
4. Connect wires to neutral safety switch and to audio warning temperature switch. Coat
connections on neutral safety switch with Quicksilver Liquid Neoprene.
50686
a
b
a-Neutral Safety Switch
b-Audio Warning Temperature Switch
Functional Tests
1. Connect a pressure gauge and thermometer to fluid pump at locations shown.
50686
a
b
a-Pressure Gauge (m10x1 Thread - Remove Plug)
b-Thermometer (3/8 In. Thread) - Remove Temperature Sender
2. Perform functional tests as shown in chart following. Refer to “Operating Specifications”
for correct readings.
Tests to Be Carried Out:
1. Leakages
2. Noise emission
3. Direction of rotation, LH/RH
4. Fluid temperature
5. Shifting pressure