Do you have a question about the METREL A 1532 XA and is the answer not in the manual?
input voltage | up to 250 V (1-phase), up to 430 V (3-phase) |
---|---|
frequency | 50 Hz, 60 Hz |
maximum test current | 267 A (10 ms) intermittent operation |
maximum load current | 13 A, continuous operation |
resistance BNC case to PE | 100 kΩ |
resistance BNC contact to CP | 100 kΩ |
altitude | up to 3000 meters above sea level |
working temperature range | 0 °C … 40 °C |
---|---|
maximum relative humidity (operation) | 95 %RH (0 °C … 40 °C), non-condensing |
storage temperature range | -10 °C … +70 °C |
maximum relative humidity (storage) | 90 %RH (-10 °C … +40 °C), 80 %RH (40 °C … 60 °C) |
dimensions | 10 cm × 7 cm × 25 cm |
---|---|
test lead(s) length | 0.5 m |
weight | 0.90 kg |
General warnings and notes for safe operation of the EVSE adapter, emphasizing reading the manual.
Explanation of CE marking, recycling symbol, and insulation marking on the adapter.
List of safety (LVD) and functional standards the EVSE adapter complies with.
Diagrams illustrating the connection of the A 1532 XA to EVSE and installation testers.
Steps for performing safety and functional tests, including setting PP STATE and CP STATE.
Description of PP STATE selector positions and their simulated EV cable current ratings.
Explanation of CP STATE selector positions simulating EV charging states and ventilation requirements.
Details on fault simulation buttons for diode short, PE open, and CP short to PE via diode.
Procedure for checking the Control Pilot (CP) signal using an oscilloscope.
Instructions for cleaning the adapter's housing using a soft cloth and mild cleaning agents.
Guidance on contacting the distributor for warranty repairs or other service needs.
Comprehensive list of electrical, dimensional, and operational specifications for the EVSE adapter.