EasyManua.ls Logo

METREL A 1532 XA User Manual

METREL A 1532 XA
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
METREL test and measurement accessories:
EVSE adapter
A 1532 XA
Instruction manual
Version 1.1.1, Code no. 20 753 114
Question and Answer IconNeed help?

Do you have a question about the METREL A 1532 XA and is the answer not in the manual?

METREL A 1532 XA Specifications

General Data IconGeneral Data
input voltageup to 250 V (1-phase), up to 430 V (3-phase)
frequency50 Hz, 60 Hz
maximum test current267 A (10 ms) intermittent operation
maximum load current13 A, continuous operation
resistance BNC case to PE100 kΩ
resistance BNC contact to CP100 kΩ
altitudeup to 3000 meters above sea level
Operating Conditions IconOperating Conditions
working temperature range0 °C … 40 °C
maximum relative humidity (operation)95 %RH (0 °C … 40 °C), non-condensing
storage temperature range-10 °C … +70 °C
maximum relative humidity (storage)90 %RH (-10 °C … +40 °C), 80 %RH (40 °C … 60 °C)
Weight and Dimensions IconWeight and Dimensions
dimensions10 cm × 7 cm × 25 cm
test lead(s) length0.5 m
weight0.90 kg

Summary

Document Preface

Safety and Operation

Safety Warnings and Notes

General warnings and notes for safe operation of the EVSE adapter, emphasizing reading the manual.

Adapter Markings and Symbols

Explanation of CE marking, recycling symbol, and insulation marking on the adapter.

Applicable Standards

List of safety (LVD) and functional standards the EVSE adapter complies with.

EVSE Adapter Components

Operating the EVSE Adapter

Connection Diagrams

Diagrams illustrating the connection of the A 1532 XA to EVSE and installation testers.

Performing Safety and Functional Tests

Steps for performing safety and functional tests, including setting PP STATE and CP STATE.

PP STATE Simulation Settings

Description of PP STATE selector positions and their simulated EV cable current ratings.

CP STATE Simulation Settings

Explanation of CP STATE selector positions simulating EV charging states and ventilation requirements.

Fault Simulation Procedures

Details on fault simulation buttons for diode short, PE open, and CP short to PE via diode.

CP Signal Measurement

Procedure for checking the Control Pilot (CP) signal using an oscilloscope.

Device Maintenance

Cleaning Instructions

Instructions for cleaning the adapter's housing using a soft cloth and mild cleaning agents.

Service and Repairs

Guidance on contacting the distributor for warranty repairs or other service needs.

Technical Specifications Overview

General Technical Data

Comprehensive list of electrical, dimensional, and operational specifications for the EVSE adapter.

Related product manuals