FIGURE 3-86
Torque the bolts to 100-125 in. lbs. using a 1/4” hex key or
Allen Socket.
-60-
REASSEMBLY - ALL MODELS
FIGURE 3-84
Install cover assembly using mallet to seat cover, making
certain filter plug is properly located next to the electric
motor.
FIGURE 3-85
Drain plug and filters to be torqued to 75-85 in. lbs. with
an 11/16” hex socket. Remove nuts from pump studs and
screw into base.
FIGURE 3-83
Reinstall reservoir using mallet to seat reservoir squarely.