84
Measure distance D by means of a slide calipers.
1. After first measuring of a new machine or a new conveyor, insert the
numerical value in the square above the diagrams.
2. After subsequent measurings. Calculate the wear and plot it in one of the
diagrams.
Note: The slide calipers must always face in the same direction when measuring.
Lubricate the threads of the screw with castor oil or ball bearing grease. Tighten the screw.
Tighten torque: 22 Nm (2.2 kpm).