EasyManua.ls Logo

MICRO-EPSILON optoNCDT ILR 102 series - Target Dimensions ILR1020; Factory Setting

MICRO-EPSILON optoNCDT ILR 102 series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 26
Operation
optoNCDT ILR 102x/110x/115x
6.1.4 Target Dimensions ILR1020
10
9
8
7
6
5
4
3
2
1
0
Side length in mm
Distance in m
Smallest detectable part in relation to the distance.
This chart shows typical values measured on a square, white object.
6.1.5 Factory Setting
ILR1020 ILR1021
Analog output 0 % 4 mA (6000 mm) 4 mA (30000 mm)
Analog output 100 % 20 mA (200 mm) 20 mA (200 mm)
Switching output Q
A
600 mm N.O.
Switching output Q
B
2500 mm N.O.