6.1.2 Switching Point, Analog Output, SLOW/FAST Mode
Open control menu Q
A
Setup
Press the Set key for 3 seconds.
For all settings given below, the sensor
has to be in the control menu.
During this time, the target laser used for
mounting the sensor is switched on auto-
matically. In this mode the sensor works
only with a reduced switching frequency.
Leave control menu (ESC)
The menu can be left at any point.
Press the Set and Toggle keys
simultaneously for 1 second.
When leaving the control menu the
target laser is switched off automatically.
Q
A
Q
B
S T
Setting switching point Q
A
Press the Toggle key until the
menu LED SA1 lights up.
Position the reflector at the desired
switching point and press the Set
key.
Q
A
Q
B
S T
Setting switching window Q
A
Press the Toggle key until the
menu LED SA1 lights up.
Position the reflector at the desired
first switching point and press the
Set key.
Q
A
Q
B
S T
Press the Toggle key until the
menu LED SA2 lights up.
Position the reflector to the desired
second switching point and press
the Set key.
Q
A
Q
B
S T
Invert switching output Q
A
Press the Toggle key until the
menu LEDs SA1 and SA2 light up.
Press the Set key.
The output signal is inverted.