6.2.12 Factory Preset
All settings are reset to delivery state. Go to the Factory Preset menu, see Chap. A 2.
6.2.13 Password
Go to the Password menu to activate/deactivate the password protection. With delivery the password pro-
tection is not active.
The password is permanently 1234 and cannot be changed. When the sensor is set to Password ON it is
only possible to quit operating mode when 1234 has been entered as password. Measuring mode continues
in the background while the password is being entered. Should no entry be made in the password input
menu over a period of approximately 10 seconds the operating mode reappears on the display.
7. Instructions for Operation
Alignment can be carried out with the aid of the integrated visible target laser.
Observe the information pictured below when aligning the sensors.
Wrong!
Shadowing
through
target
Right
Direction of movement
Rotating shaft
Right
Wrong!