9. Technical specifications:
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . .400 g (including batteries)
Dimensions: . . . . . . . . . . . . . . . . . . . . . . . .140 x 110 x 70 mm
Storage temperature: . . . . . . . . . . . . . . . .-4 to 131°F (-20 to 55°C)
Humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . .15 to 90% relative humidity
maximum
Operating temperature: . . . . . . . . . . . . . .50 to 104°F (10 to 40°C)
Display: . . . . . . . . . . . . . . . . . . . . . . . . . . . .LCD (Liquid Crystal Display)
Measuring method: . . . . . . . . . . . . . . . . . .Oscillometric
Pressure sensor: . . . . . . . . . . . . . . . . . . . .Capacitive
Measuring range:
SYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 to 255 mmHg
DIA: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 to 200 mmHg
Pulse: . . . . . . . . . . . . . . . . . . . . . . . . . . .40 to 299 mmHg
Cuff pressure display range: . . . . . . . . . .0-299 mmHg
Memory: . . . . . . . . . . . . . . . . . . . . . . . . . . .Automatically stores last
measurement
Measuring resolution: . . . . . . . . . . . . . . .1 mmHg
Accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . .Pressure within ± 3 mmHg or 2%
of reading >200mmHg
Pulse ± 5 % of the reading
Power source: . . . . . . . . . . . . . . . . . . . . . .4 AA batteries, 1.5 V
Accessories: . . . . . . . . . . . . . . . . . . . . . . .regular cuff for arm circumference
9.5”-13.25”
Technical alterations reserved.
Made in China
21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microlife BP3AQ1-1 and is the answer not in the manual?

Microlife BP3AQ1-1 Specifications

General IconGeneral
ModelBP3AQ1-1
TypeUpper Arm Blood Pressure Monitor
Measurement MethodOscillometric
DisplayLCD
Measurement Range (Blood Pressure)0 - 299 mmHg
Accuracy (Blood Pressure)±3 mmHg
InflationAutomatic
DeflationAutomatic
Cuff Size22-32 cm
Measurement Range (Pulse)40 - 180 beats per minute
Accuracy (Pulse)±5% of reading
Memory30 measurements
Power Supply4 x 1.5 V batteries size AA
Operating Temperature10 - 40 °C
Operating Humidity15 - 85% RH
Storage Temperature-20 - 60 °C
Storage Humidity10 - 95% RH
Weight300 g
Additional FeaturesIrregular Heartbeat Detection