3 consecutive readings ( Measurement Average Mode = 3/MAM-mode )
In the case of a single reading, just one blood pressure reading is taken and stored.
The 3/MAM-mode is to be recommended if you suffer from severely fluctuating blood
pressure. 3 successive readings are taken at 15 second intervals, thus eliminating
widely varying readings. In the case of serious deviations, a 4th reading may be taken.
From these three measurements, a weighted average value is calculated, displayed
and stored in the selected memory. A reading taken in this way is indicated in the
memory by an bk .
The 3/MAM procedure greatly minimizes the risk of an incorrect reading.
1. To switch between single measurement and 3 consecutive measurements (3MAM
procedure), press and hold the TIMER button W until the symbol for 3MAM mode
and appear flashing in the display.
2. Press the MEMO button x to select either “ or “; for the
3MAM measuring method and for single measurement.
3. Confirm your selection by pressing the START button w (or press the TIMER
button W to make the next setting: Switch beep on/off “).
3.7. Switching beeps on/off
Beeps sound when you take a measurement using the 3NF1-2B blood pressure meter.
You can switch off the beeps by making the following setting.
1. To switch between “beep on” and “beep off”, press and hold the TIMER button W
until and appear flashing in the display.
2. Press the TIMER button W again. ” appears in the display, followed by “
“.
3. Press the MEMO button x to switch between “ and “.
4. Confirm your selection by pressing the START button w (or press the TIMER
button W to make the next setting: Switch radio clock on/off “, see section 3,
subsection 3.3, point 4).
If you select “, the beep function remains switched off when you take
measurements.
4. Operation
4.1. Fitting the cuff
First attach the free end of the cuff’s u air tube to the designated connectorX on the
unit. Open up the preformed cuff and slip it over the bare left upper arm just above the
2G-IB-edit for NF1-2B_rev_2.3:MLU3AC1-JAN05-2 14-11-20 10:25 Page 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microlife BP3NF1-2B and is the answer not in the manual?

Microlife BP3NF1-2B Specifications

General IconGeneral
BrandMicrolife
ModelBP3NF1-2B
CategoryBlood Pressure Monitor
LanguageEnglish

Related product manuals