Operating Modes MLR003R8
4 Operating Modes MLR003R
Installatio
n cycle
Standard
operation
Idle state Radio
failure
Forced
heating
Freeze
Protection
Comments Valve target
%
Or
Room
target
temperatur
e
Phases
between
monitoring
and
communica
ting
Transmit
messages
not
received by
the
gateway
Valve opens
to 50%
(or remains
in current
position if
current
position is
>= 50%)
Valve opens
to 95%
Trigger Magnetic
switch.
Join accept
from
Gateway,
& Device is
mounted
Internal
timer
Internal
timer
From
activation:
No Gateway
connect
from
standard
operation: 6
consecutive
Gateway
communica
tion failures
Battery
voltage < 2V
Flow sensor
raw
temperatur
e
<= 6°C
Radio
communic
ation
interval
(RCI)
10 seconds
for 5
minutes
5 minutes
10 minutes
60 minutes
120
minutes
480
minutes
OFF Three times
30 seconds
Then once 2
minutes
Then 60
minutes
OFF OFF
Dynamic
change of
communic
ation
interval
No Yes No No No No