Midcontinent SAM MD302 - Pre-Flight Mode

Midcontinent SAM MD302
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REV. F Sept 15, 2015 Manual Number 9017846
2
In Pre-ight Mode, power is applied to the unit and the Introduction
Screen appears during startup (Image 1).
During Pre-ight Mode, the Introduction Screen will be displayed
while the unit conducts an initial Power-up Built-in Test (PBIT) of
the system to validate operational readiness. This includes, among
others, a battery capacity measurement, an internal test to verify
software and memory, and conrmation that the internal settings
and identication of the unit match the Conguration Module
installed in the aircraft cable harness.
The Introduction Screen will be displayed for approximately ve
seconds and will transition to Flight Mode when complete.
PRE-FLIGHT MODE
PRE-FLIGHT MODE
INTRODUCTION SCREEN
Image 1