EasyManua.ls Logo

Midea DLFSHBH12XAK - DIAGNOSIS AND SOLUTION; EEPROM Parameter Error (EH00;EH0 A)

Midea DLFSHBH12XAK
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
25
DIAGNOSIS AND SOLUTION
EEPROM Parameter Error (EH00/EH0A)
Description: The indoor or outdoor PCB main chip does not receive feedback from the EEPROM chip
Recommended parts to prepare:
Indoor PCB
Troubleshooting and Repair
Review Figure 19 for the location of the EEPROM chip on the indoor and outdoor PCB.
Fig. 19 — EEPROM Chip (Indoor Unit)
NOTE: The images within this manual are for reference only.
Shut o the power supply and
turn it on 2 minutes later.
Is it still displaying
the error code ?
YES
Replace the indoor main PCB .
The unit is operating normally.NO

Table of Contents