Service manual for Dryer Machine Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
36
STYLE B GAS VALVE
CONVERSION
7(i).1 Disconnect the 2
connectors from the valve.
7(i).2 Position a pair of long
nose pliers into the slots of
the cover dial. Rotate cover
dial 25 degrees counter
clockwise lining up ”LPG”
marking with the indicator
on the gas valve.
7(i).3 Observe the cover
dial settings indicated as
NG(Natural gas) and
LPG(Liquefied Propane
gas) along with the gas
type indicator.
7(i).4 Affix the “Rating
Plate Conversion Label”
in a conspicuous location
adjacent to the rating
plate.
7(j). Take care all
ternimals. (Gas model
only)
8. Remove the Door assy
8.1 Remove the screws on
the Door Hinge and Take
down the Door assy;
COVER
DIAL
NG
SETTING
SETTING
INDICATOR
Disconnect
Rotate