EasyManua.ls Logo

Midtronics DSS-7000

Midtronics DSS-7000
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Midtronics Inc. 7000 Monroe Street Willowbrook, IL 60527
www.midtronics.com
26
Chapter 3: Applications (Apps) DSS-7000
Battery Rating Units
CCA
CA
JIS
DIN(A)
SAE(A)
IEC(A)
EN(A)
EN2(A)
This information is usually printed on the battery label.
Rating Description Range
CCA
Cold Cranking Amps: Battery
current at 0 ºF (–17.8 ºC).
100 to 3000
CA
Cranking Amps:
Battery current
at
32°F (0 ºC).
100 to 3000
JIS
Japanese Industrial Standard:
Usually printed on battery label.
26A17 to
245H52
DIN(A) Deutsche Industrie-Norm 100 to 1000
SAE(A)
European labeling of CCA
100 to 3000
IEC(A) International Electrotechnical
Commission
100 to 1000
EN(A) Europa-Norm 100 to 1700
EN2(A)
Europa-Norm 100 to 1700
Battery Rating
?
Tap on the box and use the keypad displayed on the
Tablet Controller to enter the battery rating.
NOTE: When JIS is selected, use the drop-down
menu to scroll to the correct JIS number.
Battery Test Results
After the test the tester displays one of ve battery decisions
along with the complete results.
Tap PRINT to print the test results or EMAIL to email the
results to the customer. To return to the Home Screen, tap
DONE.
Decision Recommended Action
GOOD BATTERY Return the battery to service.
GOOD–
RECHARGE
Fully charge battery and return to
service.
CHARGE &
RETEST
Fully charge the battery and retest.
Failure to fully charge the battery
before retesting may cause false
readings. For a repeated CHARGE &
RETEST decision, replace battery.
REPLACE
BATTERY *
May also mean a poor connection
between battery cables and battery.
BAD CELL–
REPLACE
Replace the battery and retest.

Table of Contents