Problem solving guide
73
Water inlet fault
Problem Cause and remedy
All in-operation indicat-
ors are flashing quickly.
The warning buzzer is
sounding.
One of the following
faults is shown in the
display:
Water inlet fault. Please
open the stopcock
The stopcock is closed.
Open the stopcock fully.
Water inlet fault Before rectifying the problem:
Switch the dishwasher off using the sensor.
The water intake is restricted.
Open the stopcock fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than 50
kPa (0.5 bar).
Seek professional advice.
The following message
appears in the display
during the SolarSave pro-
gramme:
Water in. temp. too low
The intake water has not reached the required tem-
perature of 45°C (see "Plumbing, Connection to the
water supply").
Start the programme again.
If the fault message appears again, select a differ-
ent programme.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele HG05 and is the answer not in the manual?

Miele HG05 Specifications

General IconGeneral
TypeFreestanding
Noise Level46 dB
Drying PerformanceA
Cleaning PerformanceA
Delay StartYes
Child LockYes
Water SoftenerYes
Salt IndicatorYes
Rinse Aid IndicatorYes
ProgramsEco, Intensive, Quick

Related product manuals