Venting the dispensing system
Before the machine is first
commissioned, and later on if one or
more containers has been allowed to
run dry, the dispensing system(s) for
liquid media will need to be vented. To
do this:
^
Press the I-0 button.
^
Select operating level B.
^
Select as required:
Programme DOS1-FILL
Programme DOS2-FILL
Programme DOS3-FILL
Programme DOS4-FILL.
(See "Operation/B. Free programme
selection).
^ Press the Start button 6.
The DOS-FILL Service Programmes
are allocated to programme places
58-61 ex works, but can be
re-allocated to other programme
places, if preferred.
Dispensing system
maintenance
To ensure trouble-free operation, the
following maintenance should be
carried out by a Miele approved service
technician.
Every 12-18 months
Replace the hoses in the dispensing
system(s).
External Dispensing systems
If external pumps are used for
dispensing liquid agents, please
contact the Miele Service Department.
The instructions given in the
Programming Manual under "Machine
functions" will need to be observed.
Dispensing liquid chemical agents