6. Remove the wire jumper from inside the drum.
7. Select “20 Minutes Warm Air” in the service mode and wait for approximately
60 seconds.
The “Cooling down” LED Illuminates Circuit is In proper working order
The “Cooling down” and “Drying” LEDs
flash alternately
Circuit defective (Lifter bars
drum partially short-circuited.
Resistance is < 50 M.Ohms
8. Disconnect the wires to the drum and lifter bars at the pickup connection plug.
9. Select “20 Minutes Warm Air” in the service mode and wait for approximately
60 seconds.
The “Cooling down” LED Illuminates Check circuit outside of the Control
Electronic. (e.g.~ slip rings, wiring, lifter
bars, sensor contacts etc).
The “Cooling down” and “Drying” LEDs
flash alternately
Replace the Control Electronic.