18
Technical data
POWER SOURCE SIGMA
2
300 SIGMA
2
400 SIGMA
2
500
Mains voltage ±15% (50-60Hz)
- Autotransformer optional ±15% (50-60Hz)
3x400
3x230-500
3x400
3x230-500
3x400
3x230-500
Minimum generator size, kVA 18.5 29 36
Fuse, A 16 20 32
Mains current, effective, A 16.5 (380V)/15.7 (400) 18.2 (380 V)/17.3 (400 V) 29.3 (380V)/27.8 (400V)
Mains current, max., A 19.0 (380)/18.1 (400) 29.5 (380 V)/28.0 (400 V) 36.8 (380V)/35.0 (400V)
Power, 100%, kVA 10.9 12.0 17.9
Power, max., kVA 12.5 19.3 24.2
Power, open circuit, VA 40 40 40
Efficiency 0.87 0.88 0.90
Power factor 0.90 0.90 0.90
Current range, A 15-300 15-400 15-500
Duty cycle, 100% 20°C (MIG), A 300 330 475
Duty cycle, max. 20°C (MIG), A/% 400/70 500/80
Duty cycle, 100% 40°C (MIG), A/V 270/30.8 290/31.6 420/36.8
Duty cycle, 60% 40°C (MIG), A/V 350/34.0 450/38.0
Duty cycle, max. 40°C (MIG), A/%/V 300/80/32.0 400/40/36.0 500/55/40.0
Open circuit voltage, V 69-76 69-76 78-95
1)
Sphere of application, C
1)
Sphere of application, S
S/CE
S/CE/CCC
S/CE
S/CE/CCC
S/CE
S/CE/CCC
2)
Protection class IP 23 IP 23 IP23
Standards EN/IEC60974-1. EN/IEC60974-2. EN/IEC60974-5. EN/IEC60974-10
Dimensions C-L (HxWxL), mm
Dimensions C-W (HxWxL), mm
906x524x925
1051x524x925
906x524x925
1051x524x925
906x524x925
1051x524x925
Dimensions S-L/W (HxWxL), mm 1144x524x1031 1144x524x1031 1144x524x1031
Weight C-L, kg
Weight C-W, kg
58
69
60
71
60
71
Weight S-L, kg
Weight S-W, kg
74
85
76
87
76
87
WIRE FEED UNIT MWF 41/internal
Wire feed speed, m/min 0.5-30.0
Torch connection EURO
Wire-reel diameter, mm 300
100% duty cycle 40°C, A 420
60% duty cycle 40°C, A 500
2)
Protection class IP 23
Wire diameter, mm 0.6-2.4
Gas pressure, MPa (bar) 0.6 (6.0)
Dimensions (HxWxL), mm 440x245x780
Weight, kg 19
Standards EN/IEC60974-5.
EN/IEC60974-10
COOLING UNIT
Cooling efficiency, W 1100
Tank capacity, liter 3.5
Flow, bar - °C - l/min 1.2 - 60 - 1.75
Pressure max., bar 3
Standards EN/IEC60974-2
FUNCTION PROCESS VALUE RANGE
Selection of trigger mode MIG/MAG 2-times/4-times
Control of current/voltage/ wire feed speed - local/torch control
Wire inching MIG/MAG yes
Torch cooling - water cooled/gas cooled
Hot-start % MMA F-11 0.0-100.0
Hot-start-time, sec. MMA F-12 0.0-20.0
Arc power, % MMA F-13 0.0-150.0
Gas pre-flow, sec. MIG/MAG F-31 0.0-10.0
Soft-start, m/min MIG/MAG F-32 0.5-24.0
Hot-start, % Synergic MIG F-33 -99 - +99
Hot-start-time, sec. Synergic MIG F-34 0.0-20.0
Slope down time, sec. Synergic MIG F-35 0.0-10.0
Stop Amp, A Synergic MIG F-36 0-100
Stop Amp time, sec. Synergic MIG F-40 0.0-10.0
Reduction of voltage trim, % Synergic MIG F-71 0-50
Burn back MIG/MAG F-37 0-30
Gas post-flow, sec. MIG/MAG F-38 0.0-20.0
Sequence timer / Spot welding time, sec. MIG/MAG F-39 0.0-50.0
DUO Plus™ efficiency, %
MIG/MAG F-20 0-50
DUO Plus™ time, sec. MIG/MAG F-21 0.1-9.9
Electronic choke -5.0 - +5.0
Sequence steps 9
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: SIGMA
2
conforms to directives: 2014/35/EU
2014/30/EU
2011/65/EU
European standards: EN/IEC60974-1
EN/IEC60974-2
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Issued in Fjerritslev 17.05.2017
Niels Jørn Jakobsen
CEO
1) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.