6-12. Factory Reset (Menu 9 Of 13)
1 Lower Right Inside () Button
2 Lower Right Outside (+)
Button
3 Auto-Set Button
. A Factory Reset will reset the
primary logs data, process logs
data, error logs data, selected
process, and all process set-
tings. Motor calibration set-
tings, Spoolmate Calibration
settings, and software informa-
tion will all be retained.
Follow instructions in Section 6-3 to
enter the setup menu.
To perform a Factory Reset, press
the AutoSet button.
To exit menu, simultaneously press
and release the lower left outside
() button and lower right outside
(+) button, or turn unit off and on.
Ref. 281104-C
1
2
3
6-13. Display Software (Menu 10 Of 13)
. Display Software information is
for factory and service use
only.
Follow instructions in Section 6-3 to
enter the setup menu.
To exit menu, simultaneously press
and release the lower left outside
() button and lower right outside
(+) button, or turn unit off and on.
Ref. 281104-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miller Multimatic 235 and is the answer not in the manual?

Miller Multimatic 235 Specifications

General IconGeneral
Input Voltage120/240 V
Input Hz50 / 60 Hz
Max Output235 A
Welding ProcessesMIG, Stick, TIG, Flux-Cored
Wire Feed Speed Range50-700 IPM
Wire Size Range (Flux-Cored)0.030-0.045 in (0.8-1.2 mm)
Input PhaseSingle Phase
Wire Size Range (MIG)0.024 - 0.035 in