PL-590 XRS-5 Transducer Page 11
Mounting
Mounting
Recommendations
Mount the transducer so that it is above the maximum material level by more
than the blanking value to ensure that accurate results are achieved. Refer
to the associated transceiver manual for information on setting the blanking
value.
The transducer must be mounted so that the axis of transmission is
perpendicular to the liquid’s surface.
Do not over tighten mounting. Hand tightening of the mounting hardware is
sufficient.
Consider the optional temperature sensor when mounting the transducer.
Suspended Conduit Bracket
Flexible conduit transducer should not be
subjected to wind, vibration or jarring.
Submersible Plywood
Submersible transducer, used in
applications where flooding is possible.
Plywood mounting provides excellent
isolation, but must be rigid enough to
avoid flexing if subjected to loading.
rigid metal
conduit
coupling
transducer
rigid metal
conduit
submergence
shield
flexible conduit
steel channel
coupling
coupling
coupling