MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model
SWJ-320S
Issued
2012.07.19
Revised
2012.12.14
F/W ver
1.0
Remark
1.1
Rev.
7.1.4 List of SYSTEM HALT
List of SYSTEM HALT ?1/4?
No. LCD Cause Corrective Measures
1
SYSTEM HALT (*)
104 : +35V RECVR
35 V Power recovery error
1. Replace the DC Power Supply(36V) PCB with a new one.
(
Refer to 6.4.2)
2. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
2
SYSTEM HALT (*)
10e :FROM CLEAR
F-ROM CLEAR error (F-ROM clear unable)
F-ROM is not clearable on Parameter writ-
ing, FW down loading and Log clearing.
(fls_secclr)
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
3
SYSTEM HALT (*)
10f : FROM WRITE
FROM WRITE error (F-ROM writing
unable)
F-ROM is not clearable on Parameter writ-
ing, FW down loading and Log clearing.
(fls_secclr)
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
4
SYSTEM HALT (*)
110 : PCB KEY
No Keyboard PCB
1. Check the connections between the Keyboard PCB and the
MAIN PCB and then disconnect and connect the FFCs.
2. Replace the FFCs of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
5
SYSTEM HALT (*)
115 : PCB MAIN-F1
The F1 fuse on the MAIN PCB went out.
1. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
6
SYSTEM HALT (*)
116 : PCB MAIN-F2
The F2 fuse on the MAIN PCB went out.
7
SYSTEM HALT (*)
117 : PCB MAIN-F3
The F3 fuse on the MAIN PCB went out.
8
SYSTEM HALT (*)
11f : PCB SLIDER
No Slider PCB
.
9
SYSTEM HALT (*)
120 : LCD THERM.
LCD thermistor IC RW error
1. Check the connections between the Keyboard PCB and the
MAIN PCB, and then disconnect and connect the FFCs.
2. Replace the FFCs and the cabeles of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
5. Replace the DC Power Supply(5V) with a new one.
(
Refer to 6.4.5)
10
SYSTEM HALT (*)
122 : PRAM NONE
No PRAM
1. Update F/W.
2. Replace the PRAM PCB with a new one. (
Refer to 6.4.8)
3. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
11
SYSTEM HALT (*)
123 : PRAM DATA
PRAM data error
12
SYSTEM HALT (*)
124 : PRAM ADDR
PRAM address error
13
SYSTEM HALT (*)
125 : EEPROM READ
EEPROM read trouble
CIO Register (EER:Address 74) bit6
1. Update F/W.
2. Upload the parameter and initialize parameter with
#PARAMETER.
3. Check the connection state between MAIN PCB - Central-
IO PCB.
4. Replace the MAIN PCB with a new one. (
Refer to 3.3.1)
5. Replace the Central-IO PCB with a new one. (
Refer to 6.4.6)
14
SYSTEM HALT (*)
126 : EEPROM WR
EEPROM write trouble
CIO Register (EER:Address 74) bit
7

Table of Contents