4.2.12 MANUALhead WASH
Function
This is for removing the cap and executing suction when head cleaning is executed using a syringe (such as after head
replacement).
Procedure
1. Select [MANUALhead WASH] from the operation menu.
2. Cap OFF
3. Press [ENTER] to execute suction (operates the corresponding
pump motor). Filling will not be executed if a waste ink tank
warning is displayed.
4. Select [END] to end the operation.
<LOCAL. 1> [#01]
FUNCTION
#ADJUST <ENT>
#ADJUST
MANUALhead WASH<ent>
MANUALhead WASH
SUCTION START :ent
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > MANUALhead WASH