4.3.2 P.1
1
2
3
4
5
6
7
8
R.1.0
4.3.2 Adjustment of the Station Height
Outline
Adjust the height of the station.
Procedure
1. Remove the following covers.
• Righ cover 260
2. Loosen the two screws used for station-base adjustment.
3. Loosen the hexagon socket head screws and make an adjustment
to set their thickness gauge at 5 mm, then tighten the nuts.
4. Tighten up two loosened screws used for station-base
adjustment and fix them at 5 mm in thickness gauge.
Loosen
5mm 5mm
MAINTENANCE MANUAL > Adjustment Items > Mechanical Adjustment > Adjustment of the Station Height