© 2011 MIMAKI ENGINEERING CO.,LTD. 5.1.12 P.1
1
2
3
4
5
6
7
8
R.1.0
5.1.12 ACTION TEST
Function
Checks the operation of movable parts alone of the machine.
List of test items
Item Description
VACUUM FAN Description: Operation test of vacuum fan motor.
Set value: L.L, LOW, MID, HIGH, OFF
DRY FAN &
DEOD. FAN
Description: Optional operation test of dry/exhaust fan motor. (option)
Set value: ON, OFF
Y-CUTTER Description: Operation test of media cutter.
Set value: UP, DOWN
[FUNCTION]: Sets operation interval of Y-cutter.
[], []: Sets operation interval.
Set value: 0 – 7200 sec (unit: 1 sec)
[ENTER]: Repeats UP and Down at the set interval.
Number count is displayed during the execution.
LED POINTER Description: Operation test of LED pointer.
Set value: ON, OFF
HDC FAN Description: Operation test of HDC fan.
Set value: ON, OFF
MAINTENANCE MANUAL > Test Items > Test Function > ACTION TEST
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver
1.20
Remark
1.0