EasyManua.ls Logo

MIMAKI UJF-3042MkII User Manual

MIMAKI UJF-3042MkII
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MIMAKI ENGINEERING CO., LTD.
URL: http://mimaki.com/
URL: http://japan.mimaki.com/
D203082-10
取扱説明書の最新版は、弊社ホームページからもダウンロードできます。
You can also download the latest manual from our website.
ỶỼἜỶἈӕৢᛟଢ୿
Instruction Manual for Ionizer
Table of Contents
Before using ........................................................................... 2
Setting the Ionizer .................................................................. 2
About daily care ..................................................................... 2
Cleaning the Electrode Probe ...................................................2
Clean with Electrode Probe Cleaning Kit (SPA-0237) ..............3
Clean the electrode inner wall ..................................................4
Alarm output function............................................................ 5
イオナイザの角度調整........................................................................... 5
ご使用いただく前に .............................................................................. 6
イオナイザの設定.................................................................................. 6
お手入れについて.................................................................................. 6
除電針の清掃 .....................................................................................6
電極針クリーニングキット (SPA-0237) を使用して清掃する ...........7
電極内壁を清掃する ..........................................................................8
警報出力機能 ......................................................................................... 9
イオナイザの角度調整........................................................................... 9

Other manuals for MIMAKI UJF-3042MkII

Question and Answer IconNeed help?

Do you have a question about the MIMAKI UJF-3042MkII and is the answer not in the manual?

MIMAKI UJF-3042MkII Specifications

General IconGeneral
BrandMIMAKI
ModelUJF-3042MkII
CategoryPrinter
LanguageEnglish

Summary

Use the Optional Ionizer

Before using

Note and safety instructions for the main body and this manual are provided.

Setting the Ionizer

Instructions for enabling the static elimination operation before printing.

About daily care

Precautions and procedures for maintaining the ionizer and electrode probe.

Cleaning the Electrode Probe

Procedure for cleaning the electrode probe with alcohol and cotton swabs.

Clean with Electrode Probe Cleaning Kit (SPA-0237)

Installing Filter for SPA-0237 Cleaning Kit

Procedure for installing a new filter into the SPA-0237 electrode probe cleaning kit.

Clean the electrode inner wall

Installing Filter for SPA-0239 Cleaning Kit

Procedure for installing a new filter into Electrode Probe Cleaning Kit 2 (SPA-0239).

Alarm output function

Alarm function

Details the alarm items, symptoms, and countermeasures for the ionizer.

Ionizer Angle Adjustment

Instructions on how to move the ionizer for better access to the work area.

Related product manuals